Shortcut to content

Expertise | Expert Information | Service | New | About BAM
Contact | © Disclaimer | Site Map | Search | Deutsch
Bundesadler



Equipment and facilities

BAM Test Site Technical Safety

Explosion chamber

Tests on dangerous materials (explosives, explosive materials from the chemical industry, organic peroxides, self-decomposing materials and ammonium nitrate containing preparations) investigate their capability of conveying an induced detonation. In the explosion chamber detonation tests are used to test for example explosive production precursor-products or the detonation capability of fertilisers.

Test procedure

Detonation tests are performed in which the steel pipes are placed on proof plates and/or cylinders which are collected and assessed at the end of the tests. Tests of up to 8 kg TNT equivalent can be performed in the explosion chamber.

Technical Data

Test substance Test method Regulation
Fertiliser, preparations containing ammonium nitrate 4-in Steel Pipe Test EG Directive No. 2003/2003
Explosive production precursor-products ANE-GAP-Test UN-Test 8(b)
Propellant charge powder
(for civilian use)
DDT-Test UN Test, Test Series 5(b) (i)
Standard EN 13938-3

Abbreviations:
ANE: Ammonium nitrate emulsions
DDT: Deflagration to Detonation Transition
UN Test: Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, fourth revised edition, United Nations, New York and Geneva, 2003